Xiamen Lisen Trading Co., Ltd

  • 7SL8710-1DA10-0AA0

    7SL8710-1DA10-0AA0

    $99,999.00
    (0 reviews)

    Line differential and distance protection, Housing:flush,
    Display:small, DC 60 V-250 V, AC 100 V-230 V , 11BI, 9BO, 4xV, 4xIp, 5 Yrs.
    warrenty, base function points, Significant Feature: Two-end operation
    7SL8710-1DA10-0AA0

  • 7SL8710-1DA20-0AA0

    7SL8710-1DA20-0AA0

    $99,999.00
    (0 reviews)

    Line differential and distance protection, Housing:flush,
    Display:small, DC 24 V – 48 V, 11BI, 9BO, 4xV, 4xIp, 5 Yrs. warrenty, base
    function points, Significant Feature: Two-end operation 7SL8710-1DA20-0AA0

  • 7SR1002-1JA10-2DA0

    7SR1002-1JA10-2DA0

    $99,999.00
    (0 reviews)

    ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10
    LEDs, 3 binary inputs/ 3 binary outp. Measuring input: 1/5 A, 50/60 Hz
    auxiliary voltage: 24 to 60 V DC, binary input threshold 19 V DC Standard
    version – no cover Communication: Front port: USB . Front fascia: w. breaker
    control pushbuttons Protection function: Standard version plus autoreclose
    (79) 7SR1002-1JA10-2DA0

  • 7SR1002-1JB10-2CA0

    7SR1002-1JB10-2CA0

    $99,999.00
    (0 reviews)

    ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10
    LEDs, 3 binary inputs/ 3 binary outp. Measuring input: 1/5 A, 50/60 Hz
    auxiliary voltage: 24 to 60 V DC, binary input threshold 19 V DC Plastic
    cover with 1 pushbutton for test/reset Communication: Front port: USB . Front
    fascia: w. breaker control pushbuttons protection function: standard version
    7SR1002-1JB10-2CA0

  • 7SR1002-1JB10-2DA0

    7SR1002-1JB10-2DA0

    $99,999.00
    (0 reviews)

    ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10
    LEDs, 3 binary inputs/ 3 binary outp. Measuring input: 1/5 A, 50/60 Hz
    auxiliary voltage: 24 to 60 V DC, binary input threshold 19 V DC Plastic
    cover with 1 pushbutton for test/reset Communication: Front port: USB . Front
    fascia: w. breaker control pushbuttons Protection function: Standard version
    plus autoreclose (79) 7SR1002-1JB10-2DA0

  • 7SR1002-1KA10-2CA0

    7SR1002-1KA10-2CA0

    $99,999.00
    (0 reviews)

    Argus relay of non -fire TK modular body size 4, 4 tt, 10 SID, 3 disc.
    entrance/3 disc. The exit will measure. Entrance: 1/5 a, 50/60 Hz Auxiliary
    voltage: 60–240 B AC/DC, Discount threshold. Entrance 88 in AC/DC Standard
    version – without cover communication: front. Port: USB Fr. Panel: with
    control keys. Riacass control operating function: Standard version
    7SR1002-1KA10-2CA0

  • 7SR1002-1KA10-2DA0

    7SR1002-1KA10-2DA0

    $99,999.00
    (0 reviews)

    ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10
    LEDs, 3 binary inputs/ 3 binary outp. Measuring input: 1/5 A, 50/60 Hz
    auxiliary voltage: 60 to 240 V AC/DC, binary input threshold 88 V AC/DC
    Standard version – no cover Communication: Front port: USB . Front fascia: w.
    breaker control pushbuttons Protection function: Standard version plus
    autoreclose (79) 7SR1002-1KA10-2DA0

  • 7SR1002-1KB10-2CA0

    7SR1002-1KB10-2CA0

    $99,999.00
    (0 reviews)

    ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10
    LEDs, 3 binary inputs/ 3 binary outp. Measuring input: 1/5 A, 50/60 Hz
    auxiliary voltage: 60 to 240 V AC/DC, binary input threshold 88 V AC/DC
    Plastic cover with 1 pushbutton for test/reset Communication: Front port: USB
    . Front fascia: w. breaker control pushbuttons protection function: standard
    version 7SR1002-1KB10-2CA0

  • 7SR1002-1KB10-2DA0

    7SR1002-1KB10-2DA0

    $99,999.00
    (0 reviews)

    ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10
    LEDs, 3 binary inputs/ 3 binary outp. Measuring input: 1/5 A, 50/60 Hz
    auxiliary voltage: 60 to 240 V AC/DC, binary input threshold 88 V AC/DC
    Plastic cover with 1 pushbutton for test/reset Communication: Front port: USB
    . Front fascia: w. breaker control pushbuttons Protection function: Standard
    version plus autoreclose (79) 7SR1002-1KB10-2DA0

  • 7SR1002-1LA10-2CA0

    7SR1002-1LA10-2CA0

    $99,999.00
    (0 reviews)

    Argus relay of non -fire TK modular body size 4, 4 tt, 10 SID, 3 disc.
    entrance/3 disc. The exit will measure. Entrance: 1/5 a, 50/60 Hz Auxiliary
    voltage: 60–240 B AC/DC, Discount threshold. Entrance 44 in AC/DC Standard
    version – without cover communication: front. Port: USB Fr. Panel: with
    control keys. Riacass control operating function: Standard version
    7SR1002-1LA10-2CA0

  • 7SR1002-1LA10-2DA0

    7SR1002-1LA10-2DA0

    $99,999.00
    (0 reviews)

    ARGUS overcurrent relay Non-directional, size 4 molded case, 4 CT, 10
    LEDs, 3 binary inputs/ 3 binary outp. Measuring input: 1/5 A, 50/60 Hz
    auxiliary voltage: 60 to 240 V AC/DC, binary input threshold 44 V AC/DC
    Standard version – no cover Communication: Front port: USB . Front fascia: w.
    breaker control pushbuttons Protection function: Standard version plus
    autoreclose (79) 7SR1002-1LA10-2DA0

  • -10% 7SR1053-2JA21-2EA0

    7SR1053-2JA21-2EA0

    Original price was: $1,424.02.Current price is: $1,281.62.
    (0 reviews)

    7SR105 Size 4 Moulded case, 4 CT Inputs, 6 Binary Inputs/ 6 Binary Outputs, 10 LEDs 1/5 A, 50/60 Hz DC 24-60 V, Binary input threshold 19 VDC Standard version – No Cover Front Port: USB and Rear Port: RS-485 supporting IEC 60870-5-103 or Modbus RTU or DNP 3.0 Without RTD Standard Version – with Breaker Control Push Buttons Standard version – included–7SR1053-2JA21-2EA0

HIDE FILTER
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
Shopping cart close