3TH4271-0LB4
$99,999.00(0 reviews)Auxiliary contactor 71 E, DIN EN 50011 7 Ho + 1 NZ, a screw
clamp is connected to the varistor of a DC magnetic system operating with DC
24 V DC 3TH4271-0LB4 -
-20%
3TM3331-1TA20-0AC2
Original price was: $414.00.$331.20Current price is: $331.20.(0 reviews)Vacuum contactor 3TM three -pole estimated voltage (UR) 7.2 kV
(BIL 60 kV / PFWV 32 kV) The calculated operating current (IR) 450 A
Calculation current of shutdown at KZ (ISC), 1 s (without fuses) 5 K
controller, standard execution of a magnetic system from 24 V to 30 V DC
without blocking the inclusion and without block Electromagnetic unlocking,
re -equipment is impossible for the interdose distance of poles 120 mm
additional. Turning on the inclusion of 0 ms without supplement. shutdown
delays, unlocking voltage without unlocking additional contacts / terminal
block 4 but + 4 nz manual (English) manual 3TM3331-1TA20-0AC2 -
-20%
3UF5001-3AN00-1
Original price was: $197.14.$157.71Current price is: $157.71.(0 reviews)SIMOCODE-DP The main module Profibus-DP interface 1.5 MBAUD,
RS485 4I/40 is freely parametrated US: AC 230V, 50/60HZ 1.25-6.3A, width
70mm, entrance for connecting thermistor, monobass 3UF5001-3AN00-1 -
-20%
3UF5100-0AN00
Original price was: $207.00.$165.60Current price is: $165.60.(0 reviews)Expande module 8 inputs and 4 outputs input voltage 230V AC
Monostaby / bistabil outputs depending on the monostabil / bistabil execution
of the main module 3UF5100-0AN00 -
-20%
3UF7500-1AA00-0
Original price was: $177.43.$141.94Current price is: $141.94.(0 reviews)Module of protection against soil to earth; 1 input for
connecting a summarizing current transformer 3UL22; Maximum possible: 1
protection module for 1 base module 2 3UF7500-1AA00-0 -
3US5600-2C
$99,999.00(0 reviews)Thermal overload relay 16A-25A Dimensions 2 for 3TS35-36
ACCOLICAL/ Auto DISURATION DISCIPTION OF THE CLAMOM CLAM for Contactor coil
sensitivity to phase loss 3US5600-2C -
3US5600-2Q
$99,999.00(0 reviews)Thermal overload relay 25A-36A Mosque 2 for 3TS35-36
ACCOUNTION OF A manual/ AUTO DISURATION OF THE CLAMOTATION OF THE CLAM for
Contactor coil sensitiveness to phase loss 3US5600-2Q -
3US5600-8M
$99,999.00(0 reviews)Thermal relay overload 36A-45A SIMPLE 2 for 3TS35-36
PEPCOLICHER manual/ Auto DISURATION OF THE CLAM CLOM for Contactor coil
sensitiveness to phase loss 3US5600-8M -
3US5800-8X
$99,999.00(0 reviews)Thermal overload relay 88A-105A SIMPLE 3 To 4 for 3TS47-50 A
manual ash/ Auto DISURATION OF THE CLAMOM CLOM for Contactor coil sensitivity
to phase loss 3US5800-8X -
-20%
3VM1110-3ED12-0AA0
Original price was: $138.00.$110.40Current price is: $110.40.(0 reviews)aut. Switch 3VM1 IEC Tipping. 160 Grade of switching ability n
icu = 25 ka @ 240 in 1-floor, protection of equipment TM210, FTFM, in = 100 A
protection against overload fix. value IR = 100 A protection against short
circuits II = 10 x in flat spiral clamp 3VM1110-3ED12-0AA0 -
-20%
3VM1110-3EE32-0AA0
Original price was: $62.50.$50.00Current price is: $50.00.(0 reviews)aut. Switch 3VM1 IEC Tipping. 160 Grade of switching capacity
n icu = 25 ka @ 415 in 3-floor., Protection of equipment TM220, ATFM, in =
100 A protection against overload IR = 70 … 100 A protection against short
circuits II = 10 x in a flat screw clamp 3VM1110-3EE32-0AA0 -
-20%
3VM1116-3EE32-0AA0
Original price was: $138.00.$110.40Current price is: $110.40.(0 reviews)aut. Switch 3VM1 IEC Tipping. 160 Grade of switching capacity
n icu = 25 ka @ 415 in 3-floor., Equipment protection TM220, ATFM, in = 160 A
protection against overload IR = 112 … 160 A protection against short
circuits II = 10 x in a flat screw clamp 3VM1116-3EE32-0AA0