3LD5010-0TK13
$99,999.00(0 reviews)Sentron, 3LD5 UL, emergency circuit breaker, 3-floor, access
according to UL489, UL60947-4-1 and IEC 60947-3, UL: 30a, a calculated
short-terminal. The withstanded KZ current: 50 KA at 480 in AC, working
capacity @ 480 in AC 3-phases: 20 l. p., IEC: 32 a, working power at AC-23A
at 400 V: 15 kW, installation on a horizontal surface, including a door
clutch that is able to bypass the locks of a rotary drive, for an emergency
shutdown, a 4-screw mount of the handle, without a tolerance compensator,
VCL. terminal covers for the input (*) 3LD5010-0TK13 -
3LD5010-0TL11
$99,999.00(0 reviews)Sentron, 3LD5 UL, main circuit breaker, 4-floor, access
according to UL 489, UL60947-4-1 and IEC 60947-3, UL: 30a, the calculated
short-terminal. The withstanded KZ current: 50 KA at 480 in AC, working
capacity @ 480 in AC 3-phases: 20 l. p., IEC: 32 A, working power at AC-23A
at 400 V: 15 kW, installation on a horizontal surface, including a door
clutch that is able to bypass the locks of a rotary drive, standard, a
4-screw fastening of the handle, without a compensator of tolerances, VCL.
terminal covers for the input side 3LD5010-0TL11 -
3LD5010-0TL13
$99,999.00(0 reviews)Sentron, 3LD5 UL-UL, emergency circuit breaker, 4-floor,
admission according to UL489, UL60947-4-1 and IEC 60947-3, UL: 30a,
calculated short-term. The withstanded KZ current: 50 KA at 480 in AC,
working capacity @ 480 in AC 3-phases: 20 l. p., IEC: 32 a, working power at
AC-23A at 400 V: 15 kW, installation on a horizontal surface, including a
door clutch that is able to bypass the locks of a rotary drive, for an
emergency shutdown, a 4-screw mount of the handle, without a tolerance
compensator, VCL. terminal covers for the input (*) 3LD5010-0TL13 -
3LD5020-0TK11
$99,999.00(0 reviews)Sentron, 3LD5 UL, main circuit breaker, 3-floor, access according to UL
489, UL60947-4-1 and IEC 60947-3, UL: 30a, calculated short-term. The
withstanded KZ current: 50 KA at 480 in AC, working capacity @ 480 in AC
3-phases: 20 l. p., IEC: 32 a, working power at AC-23A at 400 V: 15 kW, with
frontal mount: rotary drive, color: black, 4-screw mounting of the handle,
including the terminal covers for the side of the inputs 3LD5020-0TK11 -
3LD5020-0TK13
$99,999.00(0 reviews)Sentron, 3LD5 UL, emergency circuit breaker, 3-floor, access according to
UL489, UL60947-4-1 and IEC 60947-3, UL: 30a, a calculated short-terminal. The
withstanded KZ current: 50 KA at 480 in AC, working capacity @ 480 in AC
3-phases: 20 l. p., IEC: 32 a, working power at AC-23A at 400 V: 15 kW, with
frontal mount: rotary drive, color: red/yellow, 4-screw mounting of the
handle, including the terminal covers for the side of the inputs
3LD5020-0TK13 -
3LD5020-0TL11
$99,999.00(0 reviews)Sentron, 3LD5 UL, main circuit breaker, 4-floor, access according to UL
489, UL60947-4-1 and IEC 60947-3, UL: 30a, the calculated short-terminal. The
withstanded KZ current: 50 KA at 480 in AC, working capacity @ 480 in AC
3-phases: 20 l. p., IEC: 32 a, working power at AC-23A at 400 V: 15 kW, with
frontal mount: rotary drive, color: black, 4-screw mounting of the handle,
including the terminal covers for the side of the inputs 3LD5020-0TL11 -
3LD5020-0TL13
$99,999.00(0 reviews)Sentron, 3LD5 UL-UL, emergency circuit breaker, 4-floor, admission
according to UL489, UL60947-4-1 and IEC 60947-3, UL: 30a, calculated
short-term. The withstanded KZ current: 50 KA at 480 in AC, working capacity
@ 480 in AC 3-phases: 20 l. p., IEC: 32 a, working power at AC-23A at 400 V:
15 kW, with frontal mount: rotary drive, color: red/yellow, 4-screw mounting
of the handle, including the terminal covers for the side of the inputs
3LD5020-0TL13 -
3LD5200-0TK11
$99,999.00(0 reviews)Sentron, 3LD5 UL, main circuit breaker, 3-floor, access according to UL
489, UL60947-4-1 and IEC 60947-3, UL: 60A, estimated short terminal. The
withstanded KZ current: 50 KA at 480 in AC, working capacity @ 480 in AC
3-phases: 40 l. p., IEC: 63A, working power at AC-23A at 400 V: 30 kW,
installation on a horizontal surface, including direct drive, color: black
vlet. terminal covers for the input side 3LD5200-0TK11 -
3LD5210-0TK11
$99,999.00(0 reviews)Sentron, 3LD5 UL, main circuit breaker, 3-floor, access
according to UL 489, UL60947-4-1 and IEC 60947-3, UL: 60A, estimated short
terminal. The withstanded KZ current: 50 KA at 480 in AC, working capacity @
480 in AC 3-phases: 40 l. p., IEC: 63A, working power at AC-23A at 400 V: 30
kW, installation on a horizontal surface, including a door clutch that is
able to bypass the locks of turning, standard, 4-screw fastening of the
handle, without a tolerance compensator, VCL. terminal covers for the input side
3LD5210-0TK11 -
3LD5210-0TK13
$99,999.00(0 reviews)Sentron, 3LD5 UL, emergency circuit breaker, 3-floor, access
according to UL489, UL60947-4-1 and IEC 60947-3, UL: 60A, a calculated
short-terminal. The withstanded KZ current: 50 KA at 480 in AC, working
capacity @ 480 in AC 3-phases: 40 l. p., IEC: 63A, working power at AC-23A at
400 V: 30 kW, installation on a horizontal surface, including a door clutch
that is able to bypass the locks of a rotary drive, for emergency shutdown, a
4-screw mounting of the handle, without a tolerance compensator, VCL. terminal
covers for the input (*) 3LD5210-0TK13 -
3LD5210-0TL11
$99,999.00(0 reviews)Sentron, 3LD5 UL, main circuit breaker, 4-floor, access
according to UL 489, UL60947-4-1 and IEC 60947-3, UL: 60A, estimated short
terminal. The withstanded KZ current: 50 KA at 480 in AC, working capacity @
480 in AC 3-phases: 40 l. p., IEC: 63A, working power at AC-23A at 400 V: 30
kW, installation on a horizontal surface, including a door clutch that is
able to bypass the locks of turning, standard, 4-screw fastening of the
handle, without a tolerance compensator, VCL. terminal covers for the input side
3LD5210-0TL11 -
3LD5210-0TL13
$99,999.00(0 reviews)Sentron, 3LD5 UL, emergency circuit breaker, 4-floor, access
according to UL489, UL60947-4-1 and IEC 60947-3, UL: 60A, a calculated
short-terminal. The withstanded KZ current: 50 KA at 480 in AC, working
capacity @ 480 in AC 3-phases: 40 l. p., IEC: 63A, working power at AC-23A at
400 V: 30 kW, installation on a horizontal surface, including a door clutch
that is able to bypass the locks of a rotary drive, for emergency shutdown, a
4-screw mounting of the handle, without a tolerance compensator, VCL. terminal
covers for the input (*) 3LD5210-0TL13