Xiamen Lisen Trading Co., Ltd

  • 6AG2522-5HF00-1AB0

    6AG2522-5HF00-1AB0

    $99,999.00
    (0 reviews)

    Автоматический выключатель 3VA6 UL frame 600 breaking capacity
    class M 35kA @ 480V 3-pole, line protection ETU850, LSI, In=600A overload
    protection ir=240A …600A short circuit protection Isd=0,6..10x In,
    iI=1,5..10x In neutral protection optional with ext. ct,upto 160% w/o
    connection 6AG2522-5HF00-1AB0

  • 6AG2526-1BH00-1AB0

    6AG2526-1BH00-1AB0

    $99,999.00
    (0 reviews)

    SIPLUS S7-1500, refusal-safety module of the discrete entrances F-DI
    16x24VDC T1 Rail, performed for reinforced concrete, operating temperature
    -25 … +55 ° C (T1 70 ° C for 10 min), with a persistent coating, based on
    6S7526-1BH00-0AB0. Refused discrete input module, F-DI 16x24VDC Profisafe; 35
    mm wide; For refusal systems up to PL E (ISO 13849-1)/ SIL3 (IEC 61508)
    6AG2526-1BH00-1AB0

  • 6AG2526-2BF00-1AB0

    6AG2526-2BF00-1AB0

    $99,999.00
    (0 reviews)

    SIPLUS S7-1500, refusal-safety module of discrete outputs F-DQ 8x24VDC/2A
    Rail, performed for reinforced concrete, operating temperature -25 … +55 °
    C (T1 70 ° C for 10 min), with persistent coating, based on
    6S7526-2BF00-0AB0. Refusable-safety module of discrete outputs, F-DQ 8x24VDC
    2A PPM Profisafe; 35 mm wide; For refusal systems up to PL E (ISO 13849-1)/
    SIL3 (IEC 61508) 6AG2526-2BF00-1AB0

  • 6AG2531-7KF00-4AB0

    6AG2531-7KF00-4AB0

    $99,999.00
    (0 reviews)

    SIPLUS S7-1500, AI 8XU/I/RTD/TC TX Rail analog inputs, for use
    on railway, operating temperature -40 … +70 ° C T1 up to 85 ° C for 10
    minutes, with a conformal coating, based on 6S7531-7KF00-0AB0. The AI ​​8 x
    U/I/RTD/TC ST, signals: current/voltage/thermal pump/thermos flow, resolution
    of 16 bits, accuracy 0.3 %, 8 channels in a group of 8, 4 channels for
    measuring thermal resistance, a total 10 V channel, diagnosis, anxiety
    messages, and v. introductory element, jumper and ground terminals 6AG2531-7KF00-4AB0

  • 6AG2531-7NF10-4AB0

    6AG2531-7NF10-4AB0

    $99,999.00
    (0 reviews)

    RSIPLUS S7-1500, AI 8xu/i Hs*-TX Rail analog inputs, for use on
    reinforced concrete, operating temperature -40 … +70 ° C TX up to 85 ° C
    for 10 minutes, with conformal coating, based on 6S7531-7NF10-0AB0. AI 8 x
    U/i HS analog entrances module: current/voltage, resolution 16 bits, 0.0625
    accuracy 0.3 %, 8 channels in a group of 8, total voltage of a total 10 V,
    diagnosis, alarming messages, vKl. introductory element, jumper and ground
    terminals 6AG2531-7NF10-4AB0

  • 6AG2532-5HD00-4AB0

    6AG2532-5HD00-4AB0

    $99,999.00
    (0 reviews)

    SIPLUS S7-1500, AQ 4XU/I ST T1 Rail analog outputs, performed for
    reinforced concrete, operating temperature -40 … +70 ° C (TX 85 ° C for 10
    min), with a persistent coating based on 6S7532-5HD00-0B0. resolution 16
    bits, accuracy 0.3 %; 4 channels in a group of 4; Diagnostics, substantive
    value, v. introductory element 6AG2532-5HD00-4AB0

  • 6AG2541-1AB00-4AB0

    6AG2541-1AB00-4AB0

    $99,999.00
    (0 reviews)

    Siplus S7-1500, communication processor CM PTP RS 422/485 TX Rail, for
    use on railway, operating temperature -40 …. +70 ° C, TX up to +85 ° C for
    10 minutes, with a conformal coating, based on 6S7541-1AB00-0AB0.
    Communication module for a sequential connection of RS 422 and 485, freely
    programmable port, 3964 (R), USS, Modbus RTU Master, SLAVE, 115200 Kbit/s
    6AG2541-1AB00-4AB0

  • 6AG2541-1AD00-4AB0

    6AG2541-1AD00-4AB0

    $99,999.00
    (0 reviews)

    SIPLUS S7-1500, CM PTP RS232 HF TX Rail communication module, with a
    persistent coating, based on 6S7541-1AD00-0AB0 operating temperature -40 …
    +70 ° C (TX 85 ° C for 10 minutes). Communication module with improved
    characteristics (HF) for a sequential connection by RS232, freely
    programmable port, 3964 (R), USS, Modbus RTU Master/Slave, 115200 Kbps,
    9-Poly Sub-D connector 6AG2541-1AD00-4AB0

  • 6AG2542-6VX00-4XE0

    6AG2542-6VX00-4XE0

    $99,999.00
    (0 reviews)

    Siplus ET 200SP, CPEMNIATION COMPETION CP
    1542SP -1 IRC TX Rail, for use on railway, operating temperature -40 …. +70
    ° C, TX up to +85 ° C for 10 minutes, with a conformal coating based on
    6GK7542-6VX00-0XE0. To connect the Simatic S7-ET 200SP to the Industrial
    Ethernet, Sinaut ST7, TeleControl Server Basic, IEC-60870-5-104 or DNP3
    6AG2542-6VX00-4XE0

  • 6AG2543-6WX00-4XE0

    6AG2543-6WX00-4XE0

    $99,999.00
    (0 reviews)

    Siplus ET 200SP, the CP 1543SP -1 ISEC TX Rail, for use on
    railway, operating temperature -40 …. +70 ° C, TX up to +85 ° C for 10
    minutes, with a conformal coating based on 6GK7543-6WX00-0XE0.
    6AG2543-6WX00-4XE0

  • 6AG2552-1AA00-4AB0

    6AG2552-1AA00-4AB0

    $99,999.00
    (0 reviews)

    SIPLUS S7-1500, TM TM TIMER DIDQ 16X24V Rail, for use on railway, OT4:
    -40 … +70 ° C ST1/2: 85 ° C for 10 minutes, with a conform coating, based
    on 6S7552-1A00-0B0. Digital entrances and exits with Max time management. 8
    di, 16 dq, of which Max. 16 with a time mark, counter, shim, first -time
    6AG2552-1AA00-4AB0

  • 6AG2620-0AA00-4AA0

    6AG2620-0AA00-4AA0

    $99,999.00
    (0 reviews)

    Siplus, PN/Can Link TX Rail, for use on reinforced concrete,
    operating temperature -40 …. +70 ° C, TX up to +85 ° C for 10 minutes, with
    a persistent coating, based on 6BK1620-0AA00-0AA0. The Profinet gateway to
    the field tire can or Canopen, Can 2.0a/b Canopen Manager or Slave according
    to CIA301/302, IP20 6AG2620-0AA00-4AA0

HIDE FILTER
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
Shopping cart close