7SJ8042-1ED90-3FB0 L0D
$99,999.00(0 reviews)MTZ with time -aging housing 1/6 19 “, 4 x I, 3 x u 7
dvx, 8 dvi (2 p) 1 Contact of serviceability measuring inputs: IF = 1 A/5 A,
INS (Sensit.) = 0.001–1.6 A/0.005–8 A Nominom. Removing voltage: DC 24, 48 B
Corps for drowned tuning, spirals The MAK/ANSI region (the language can be
changed) the front membrane Standard System Interface Port B (Lower Station,
behind) Modbus, electrician. Phase (50/51), I >>, IP Zakh. Network.
7SJ8042-1ED90-3FB0 L0D -
7SJ8042-1ED90-3FC0 L0D
$99,999.00(0 reviews)MTZ with time -aging housing 1/6 19 “, 4 x I, 3 x u 7
dvx, 8 dvi (2 p) 1 Contact of serviceability measuring inputs: IF = 1 A/5 A,
INS (Sensit.) = 0.001–1.6 A/0.005–8 A Nominom. Removing voltage: DC 24, 48 B
Corps for drowned tuning, spirals The MAK/ANSI region (the language can be
changed) the front membrane Standard System Interface Port B (Lower Station,
behind) Modbus, electrician. Phase (50/51), I>, I >>, IP Zash.
Protection against heating. 7SJ8042-1ED90-3FC0 L0D -
7SK8042-1ED90-3HE0 L0D
$99,999.00(0 reviews)Engine Protection Corps 1/6 19 “, 4 x I, 3 x U 7 DVX, 8
DVV (2 p) 1 Contact of serviceability measuring entrances: IF = 1 A/5 A, INS
(Sensit.) = 0.001–1.6 A/0.005-8 A Nominom. Removing the voltage: DC 24, 48 B
in the body of the region FR, screw terminals FR, screw terminals FR.
MAK/ANSI (you can change) the front membrane Standard System Interface Port B
(Lower Station, Higher School) Modbus, Electricity. I>, I >>, I
>>>, IP Protection from KZ to the Earth MTZ Earth (50n/51n) Iz>,
Iz >>, Iz >>>, INP.P.P.P. Protection from KZ to Earth InS>,
INS >>, INS.PA. PROCOPARIS (49) Control of the circuit circuit (74TC)
level (50BF), protection against non -membrane. Heating (46) Blocking control
(48) Control reduction (37) Prohibition of re -launch (66/86) Protection from
the lock (14) Protection from the Rotor (51M). 7SK8042-1ED90-3HE0 L0D -
7SR4503-1GA10-1AA0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45,
measuring input: 1 A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI /
2 BO, auxiliary voltage: self powered (CT powered : BI threshold 19VDC),
front fascia: standard, front port: USB, standard version: No conformal
coating on PCBA 7SR4503-1GA10-1AA0 -
7SR4503-1GA10-1AB0
$99,999.00(0 reviews)Автоматический выключатель 3VA6 UL frame 250 breaking capacity
class M 35kA @ 480V 3-pole, line protection ETU850, LSI, In=250A overload
protection ir=100A …250A short circuit protection Isd=0,6..10x In,
iI=1,5..10x In neutral protection optional with ext. ct,upto 160% w/o
connection 7SR4503-1GA10-1AB0 -
7SR4503-1GB10-1AA0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45, measuring input: 1
A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI / 2 BO, auxiliary
voltage: self powered (CT powered : BI threshold 19VDC), front fascia:
standard with trip flag indicator, front port: USB, standard version – No
conformal coating on PCBA 7SR4503-1GB10-1AA0 -
7SR4503-1GB10-1AB0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45,
measuring input: 1 A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI /
2 BO, auxiliary voltage: self powered (CT powered : BI threshold 19VDC),
front fascia: standard with trip flag indicator, front port: USB, conformal
coat: conformal coating on PCBA 7SR4503-1GB10-1AB0 -
7SR4503-1HA20-1AA0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45, measuring input: 1
A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI / 2 BO, auxiliary
voltage: dual powered (CT powered: + aux.: 24-60V DC, BI threshold 19VDC),
front fascia: standard, front port: USB and Rear port: RS485, IEC-60870-5-103
or Modbus conformal coat: standard version, no conformal coating
7SR4503-1HA20-1AA0 -
7SR4503-1HA20-1AB0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45, measuring input: 1
A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI / 2 BO, auxiliary
voltage: dual powered (CT powered: + aux.: 24-60V DC, BI threshold 19VDC),
front fascia: standard, front port: USB and Rear port: RS485, IEC-60870-5-103
or Modbus conformal coat: conformal coating on PCBA 7SR4503-1HA20-1AB0 -
7SR4503-1JA20-1AA0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45, measuring input: 1
A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI / 2 BO, auxiliary
voltage: dual powered (CT powered: + aux.: 60-240 V AC/DC, BI threshold 88 V
AC/DC), front fascia: standard, front port: USB and Rear port: RS485,
IEC-60870-5-103 or Modbus conformal coat: standard version, no conformal
coating 7SR4503-1JA20-1AA0 -
7SR4503-1JA20-1AB0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45, measuring input: 1
A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI / 2 BO, auxiliary
voltage: dual powered (CT powered: + aux.: 60-240 V AC/DC, BI threshold 88 V
AC/DC), front fascia: standard, front port: USB and Rear port: RS485,
IEC-60870-5-103 or Modbus conformal coat: conformal coating on PCBA
7SR4503-1JA20-1AB0 -
7SR4503-2GA10-1AA0
$99,999.00(0 reviews)Non-Directional Overcurrent Protection – Argus 7SR45 measuring
input: 5 A, 50/60 Hz, size 4 moulded case (height reduced), 2 BI / 2 BO,
auxiliary voltage: self powered (CT powered : BI threshold 19VDC), front
fascia: standard, front port: USB, conformal coat: No conformal coating on
PCBA 7SR4503-2GA10-1AA0